Transferência robótica de ramo do nervo axilar para tríceps
Publicado em: 2 de fevereiro de 2021 por Naeon
Publicações Científicas
Microcirurgia para retorno de movimento de tríceps em pacientes com lesão do nervo radial alta. Ou lesão do plexo com axilar íntegro.
Publicado on-line no periódico Chirurgie de la Main em 11 de Junho de 2013
Feasibility of an endoscopic approach to the axillary nerve and the nerve to the long head of the triceps brachii with the help of the Da Vinci Robot
Faisabilité d?un abord endoscopique du nerf axillaire et du nerf du chef long du triceps brachial grâce au robot Da Vinci
P.M. Porto de Meloa, b, J.C. Garciaa, E.F. de Souza Monteroc, T. AtikdE,G. Roberte, S. Faccae, P.-A. Liverneauxe,f,
a Center for Advanced Studies in Orthopedics and Neurosurgery, São Paulo, Brazil
b Neurosurgery Department, São Paulo Military Área Hospital, Brazilian Army, São Paulo, Brazil
c Department of Surgery, LIM-62, FMUSP, University of São Paulo, São Paulo, Brazil
d Central Jersey Hand Surgery, PA, Eatontown, NJ, USA
e Department of Hand Surgery, Strasbourg University Hospitals, 10, avenue Baumann, 67403 Illkirch cedex, France
f École européenne de chirurgie, université Paris Descartes, 45, rue des Saints-Pères, 75006 Paris, France
Veja: http://www.ncbi.nlm.nih.gov/pubmed/term=Feasibility+of+an+endoscopic+approach+to+the+axillary+nerve+and+the+nerve+to+the+long+head+of+the+triceps+brachii+with+the+help+of+the+Da+Vinci+robotI
Abstract
Surgery to transfer the axillary nerve and the nerve of the long head of the triceps presents two obstacles: 1) the access portals are not standardized and 2) the nerves are for their larger part approached through large incisions. The goal of this study was to explore the feasibility of an endoscopic microsurgical approach. The posterior aspect of a cadaver shoulder was approached through three communicating mini-incisions. The Da Vinci robot camera was installed on a central trocart, and the instrument arms on the adjacent trocarts. A gas insufflation distended the soft tissues up to the lateral axillary space. The branches of the axillary nerve and the nerve to the long head of the triceps brachii muscle were identified. The dissection of the axillary nerve trunk and its branches was easy. The posterior humeral circumflex veins and artery were dissected as well without any difficulty. Finding the nerve to the long head of the triceps brachii was found to be more challenging because of its deeper location. Robots properties allow performing conventional microsurgery: elimination of the physiologic tremor and multiplication of the movements. They also facilitate the endoscopic approach of the peripheral nerves, as seen in our results on the terminal branches of the axillary nerve and the nerve to the long head of the triceps brachii.
Résumé
Les transferts chirurgicaux du nerf axillaire et du nerf du chef long du triceps brachial présentent deux obstacles : 1) les voies d?abord ne sont pas standardisées et 2) les nerfs sont, pour leur plus grande partie, abordés à travers de larges incisions. Le but de cette étude était d?explorer la faisabilité d?une voie d?abord endoscopique microchirurgicale. La face postérieure d?une épaule de cadavre a été abordée par l?intermédiaire de trois mini-incisions communiquant les unes avec les autres. La caméra du robot Da Vinci a été installée sur le trocart central et les bras instrumentaux sur les trocarts adjacents. Une insufflation de gaz a distendu les parties molles jusqu?à l?espace axillaire latéral. Les branches du nerf axillaire et le nerf du chef long du triceps brachial ont été identifiés. La dissection du tronc du nerf axillaire et de ses branches fut aisée. L?artère et les veines circonflexes humérales postérieures furent disséquées également sans difficulté. La découverte du nerf du chef long du triceps brachial fut plus difficile en raison de sa localisation plus profonde. Les propriétés des robots permettent la réalisation d?une microchirurgie conventionnelle : élimination du tremblement physiologique et démultiplication des mouvements. Ils facilitent de la même façon l?abord endoscopique des nerfs périphériques, comme dans notre étude celle des branches terminales du nerf axillaire et du nerf du chef long du triceps brachial.
Keywords
Endoscopic microsurgery; Robot; Da Vinci
Mots clés
Chirurgie endoscopique; Robot; Da Vinci